Three-stage synchronous overmodulation control of five-phase inverters
Închide
Conţinutul numărului revistei
Articolul precedent
Articolul urmator
907 0
SM ISO690:2012
OLESCIUK, Valentin, GRIVA, Giovanni, PRUDEAK, Roman, SIZOV, Alexandr. Three-stage synchronous overmodulation control of five-phase inverters . In: Problemele Energeticii Regionale, 2010, nr. 1(12), pp. 28-40. ISSN 1857-0070.
EXPORT metadate:
Google Scholar
Crossref
CERIF

DataCite
Dublin Core
Problemele Energeticii Regionale
Numărul 1(12) / 2010 / ISSN 1857-0070

Three-stage synchronous overmodulation control of five-phase inverters

Pag. 28-40

Olesciuk Valentin, Griva Giovanni, Prudeak Roman, Sizov Alexandr
 
 
 
Disponibil în IBN: 16 decembrie 2013


Rezumat

Novel three-stage algorithm of synchronous PWM control of five-phase inverter in the zone of overmodulation has been proposed and investigated. It provides smooth transition from linear modulation range to the ten-step operation mode of five-phase system at the maximum fundamental frequency, with full DC-bus voltage utilization. Simulations give the behavior of five-phase system during synchronous PWM control in the zone of overmodulation.

Este elaborat şi cercetat un algoritm original de reglare sincronă prin trei etape a invertorului cu cinci faze în zonă de supramodulare, ce asigură trecerea lentă de la zonă modulării lineare la tensiunea fazale de ieşire cu zece trepte a frecvenţei maximale de ieşire a invertorului. Sunt enumărate rezultatele modelarii regimurilor de bază ale funcţionării sistemelor de conversie cincifazate în zonă frecvenţelor majorate de ieşire.

Разработан и исследован оригинальный алгоритм синхронного трехэтапного регулирования пятифазного инвертора в зоне сверхмодуляции, обеспечивающий плавный переход от зоны линейной модуляции к десятиступенчатому выходному фазному напряжению на максимальной выходной частоте инвертора. Приведены результаты моделирования базовых режимов работы пятифазной преобразовательной системы в зоне повышенных выходных частот.

Cuvinte-cheie
five-phase voltage source inverter, synchronous pulsewidth modulation, increased output frequencies, smooth linear output voltage control

Crossref XML Export

<?xml version='1.0' encoding='utf-8'?>
<doi_batch version='4.3.7' xmlns='http://www.crossref.org/schema/4.3.7' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' xsi:schemaLocation='http://www.crossref.org/schema/4.3.7 http://www.crossref.org/schema/deposit/crossref4.3.7.xsd'>
<head>
<doi_batch_id>ibn-9407</doi_batch_id>
<timestamp>1715028131</timestamp>
<depositor>
<depositor_name>Information Society Development Instiute, Republic of Moldova</depositor_name>
<email_address>idsi@asm.md</email_address>
</depositor>
</head>
<body>
<journal>
<journal_metadata>
<full_title>Problemele Energeticii Regionale</full_title>
<issn media_type='print'>18570070</issn>
</journal_metadata>
<journal_issue>
<publication_date media_type='print'>
<year>2010</year>
</publication_date>
<issue>1(12)</issue>
</journal_issue>
<journal_article publication_type='full_text'><titles>
<title>Three-stage synchronous overmodulation control of five-phase inverters
</title>
</titles>
<contributors>
<person_name sequence='first' contributor_role='author'>
<given_name>Valentin</given_name>
<surname>Olesciuk</surname>
</person_name>
<person_name sequence='additional' contributor_role='author'>
<given_name>Giovanni</given_name>
<surname>Griva</surname>
</person_name>
<person_name sequence='additional' contributor_role='author'>
<given_name>Roman</given_name>
<surname>Prudeak</surname>
</person_name>
<person_name sequence='additional' contributor_role='author'>
<given_name>Alexandr</given_name>
<surname>Sizov</surname>
</person_name>
</contributors>
<publication_date media_type='print'>
<year>2010</year>
</publication_date>
<pages>
<first_page>28</first_page>
<last_page>40</last_page>
</pages>
</journal_article>
</journal>
</body>
</doi_batch>