Conţinutul numărului revistei |
Articolul precedent |
Articolul urmator |
61 0 |
Căutarea după subiecte similare conform CZU |
616.441-006-073.43 (2) |
Patologia sistemului limfatic, a organelor hemopoietice şi endocrine (195) |
SM ISO690:2012 STOIAN, Dana, CRACIUNESCU, Mihaela, CRAINA, Marius, VARCUS, Florian, PANTEA, Stelian. False positive results of real-time elastography in the diagnosis of thyroid nodal lesions. In: Moldovan Medical Journal, 2018, nr. 61(S_RMI), p. 54. ISSN 2537-6373. |
EXPORT metadate: Google Scholar Crossref CERIF DataCite Dublin Core |
Moldovan Medical Journal | ||||||
Numărul 61(S_RMI) / 2018 / ISSN 2537-6373 /ISSNe 2537-6381 | ||||||
|
||||||
CZU: 616.441-006-073.43 | ||||||
Pag. 54-54 | ||||||
|
||||||
Descarcă PDF | ||||||
Rezumat | ||||||
Introduction: Real-time elastography is an imaging method that adds quality to the diagnosis of nodular thyroid lesions. Meta-analysis data suggest a good diagnostic performance with an overall specificity of 80% and sensitivity of 85%. The present study is a retrospective analysis of the most common causes of false negative and false positive results encountered in thyroid ultrasound. Material and methods: We analyzed 433 nodular lesions, operated and evaluated by classical thyroid ultrasound and elastography, using a linear probe on a Hitachi Preirus machine, Hitachi Inc., Japan: The results of the ultrasound were not communicated to the pathologist. A retrospective analysis of the results was performed. Results: We evaluated 433 thyroid nodules with an average volume of 2.14 ml (ranging from 0.78 ml to 10.45 ml). 134/433 cases were identified with thyroid cancer and 251/434 were identified as benign lesions. The sensitivity of the elastography was 82.02%, the specificity – 83.94%, the accuracy being 83.37%. We observed 48 cases of benign lesions, identified by elastography as suspicious lesions : 23/48 – lesions with Hürthle cells, without vascular diseases, 8/48 – proliferative lesions potentially uncertain, 5/48 – follicular proliferation, 8/48 – myxomatous / granulomatous thyroiditis and 12/48 cases of autoimmune thyroid disease. We also noted 24 false negative results: 19 / 24 – papillary microcarcinomas, 5/25 – follicular carcinomas. Of note is that microcarcinomas that have been observed in nodules, had > 3.5 cm in diameter. Conclusions: Hurtle cell proliferations and papillary microcarcinomas are the most common misdiagnosed conditions in thyroid elastography. |
||||||
Cuvinte-cheie classical thyroid ultrasound and elastography, nodal thyroid lesions |
||||||
|
DataCite XML Export
<?xml version='1.0' encoding='utf-8'?> <resource xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' xmlns='http://datacite.org/schema/kernel-3' xsi:schemaLocation='http://datacite.org/schema/kernel-3 http://schema.datacite.org/meta/kernel-3/metadata.xsd'> <creators> <creator> <creatorName>Stoian, D.</creatorName> <affiliation>Universitatea de Medicină şi Farmacie „Victor Babes“, Timişoara, România</affiliation> </creator> <creator> <creatorName>Craciunescu, M.</creatorName> <affiliation>Universitatea de Medicină şi Farmacie „Victor Babes“, Timişoara, România</affiliation> </creator> <creator> <creatorName>Craina, M.</creatorName> <affiliation>Universitatea de Medicină şi Farmacie „Victor Babes“, Timişoara, România</affiliation> </creator> <creator> <creatorName>Varcus, F.</creatorName> <affiliation>Universitatea de Medicină şi Farmacie „Victor Babes“, Timişoara, România</affiliation> </creator> <creator> <creatorName>Pantea, S.</creatorName> <affiliation>Universitatea de Medicină şi Farmacie „Victor Babes“, Timişoara, România</affiliation> </creator> </creators> <titles> <title xml:lang='en'>False positive results of real-time elastography in the diagnosis of thyroid nodal lesions</title> </titles> <publisher>Instrumentul Bibliometric National</publisher> <publicationYear>2018</publicationYear> <relatedIdentifier relatedIdentifierType='ISSN' relationType='IsPartOf'>2537-6373</relatedIdentifier> <subjects> <subject>classical thyroid ultrasound and elastography</subject> <subject>nodal thyroid lesions</subject> <subject schemeURI='http://udcdata.info/' subjectScheme='UDC'>616.441-006-073.43</subject> </subjects> <dates> <date dateType='Issued'>2018-06-04</date> </dates> <resourceType resourceTypeGeneral='Text'>Journal article</resourceType> <descriptions> <description xml:lang='en' descriptionType='Abstract'><p>Introduction: Real-time elastography is an imaging method that adds quality to the diagnosis of nodular thyroid lesions. Meta-analysis data suggest a good diagnostic performance with an overall specificity of 80% and sensitivity of 85%. The present study is a retrospective analysis of the most common causes of false negative and false positive results encountered in thyroid ultrasound. Material and methods: We analyzed 433 nodular lesions, operated and evaluated by classical thyroid ultrasound and elastography, using a linear probe on a Hitachi Preirus machine, Hitachi Inc., Japan: The results of the ultrasound were not communicated to the pathologist. A retrospective analysis of the results was performed. Results: We evaluated 433 thyroid nodules with an average volume of 2.14 ml (ranging from 0.78 ml to 10.45 ml). 134/433 cases were identified with thyroid cancer and 251/434 were identified as benign lesions. The sensitivity of the elastography was 82.02%, the specificity – 83.94%, the accuracy being 83.37%. We observed 48 cases of benign lesions, identified by elastography as suspicious lesions : 23/48 – lesions with Hürthle cells, without vascular diseases, 8/48 – proliferative lesions potentially uncertain, 5/48 – follicular proliferation, 8/48 – myxomatous / granulomatous thyroiditis and 12/48 cases of autoimmune thyroid disease. We also noted 24 false negative results: 19 / 24 – papillary microcarcinomas, 5/25 – follicular carcinomas. Of note is that microcarcinomas that have been observed in nodules, had > 3.5 cm in diameter. Conclusions: Hurtle cell proliferations and papillary microcarcinomas are the most common misdiagnosed conditions in thyroid elastography.</p></description> </descriptions> <formats> <format>application/pdf</format> </formats> </resource>