![]() AMBROS, Tudor, URSATII, Nicolai. Armature’s reaction in synchronous devices with smooth magnetic gap. In: Conference on Electrical and Power Engineering, 28-30 octombrie 2010, Iași. Iași, România: Technical University “Gheorghe Asachi” of Iași, 2010, Editia 6-a, Vol. 2, pp. 150-152. ISBN 978-606-13-0079-2; 978-606-13-0078-5. |
EXPORT metadate: Google Scholar Crossref CERIF DataCite Dublin Core |
Conference on Electrical and Power Engineering Editia 6-a, Vol. 2, 2010 |
||||||
Conferința "Conference on Electrical and Power Engineering" Iași, Romania, 28-30 octombrie 2010 | ||||||
|
||||||
Pag. 150-152 | ||||||
|
||||||
![]() |
||||||
Rezumat | ||||||
The paperwork illustrates a synchronous generator with permanent magnets where the winding is mounted directly on the interior side of the no slotted armature, which simplifies the design technology for this type of generator. It is proved that the armature’s reaction is six times reduced, approximately, the toothing harmonics are removed and the external feature is a lot more rigid as compared to the classical generator. |
||||||
|
Cerif XML Export
<?xml version='1.0' encoding='utf-8'?> <CERIF xmlns='urn:xmlns:org:eurocris:cerif-1.5-1' xsi:schemaLocation='urn:xmlns:org:eurocris:cerif-1.5-1 http://www.eurocris.org/Uploads/Web%20pages/CERIF-1.5/CERIF_1.5_1.xsd' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' release='1.5' date='2012-10-07' sourceDatabase='Output Profile'> <cfResPubl> <cfResPublId>ibn-ResPubl-163389</cfResPublId> <cfResPublDate>2010</cfResPublDate> <cfVol>Editia 6-a, Vol. 2</cfVol> <cfStartPage>150</cfStartPage> <cfISBN>978-606-13-0079-2; 978-606-13-0078-5</cfISBN> <cfURI>https://ibn.idsi.md/ro/vizualizare_articol/163389</cfURI> <cfTitle cfLangCode='EN' cfTrans='o'>Armature’s reaction in synchronous devices with smooth magnetic gap</cfTitle> <cfAbstr cfLangCode='EN' cfTrans='o'><p>The paperwork illustrates a synchronous generator with permanent magnets where the winding is mounted directly on the interior side of the no slotted armature, which simplifies the design technology for this type of generator. It is proved that the armature’s reaction is six times reduced, approximately, the toothing harmonics are removed and the external feature is a lot more rigid as compared to the classical generator.</p></cfAbstr> <cfResPubl_Class> <cfClassId>eda2d9e9-34c5-11e1-b86c-0800200c9a66</cfClassId> <cfClassSchemeId>759af938-34ae-11e1-b86c-0800200c9a66</cfClassSchemeId> <cfStartDate>2010T24:00:00</cfStartDate> </cfResPubl_Class> <cfResPubl_Class> <cfClassId>e601872f-4b7e-4d88-929f-7df027b226c9</cfClassId> <cfClassSchemeId>40e90e2f-446d-460a-98e5-5dce57550c48</cfClassSchemeId> <cfStartDate>2010T24:00:00</cfStartDate> </cfResPubl_Class> <cfPers_ResPubl> <cfPersId>ibn-person-755</cfPersId> <cfClassId>49815870-1cfe-11e1-8bc2-0800200c9a66</cfClassId> <cfClassSchemeId>b7135ad0-1d00-11e1-8bc2-0800200c9a66</cfClassSchemeId> <cfStartDate>2010T24:00:00</cfStartDate> </cfPers_ResPubl> <cfPers_ResPubl> <cfPersId>ibn-person-26483</cfPersId> <cfClassId>49815870-1cfe-11e1-8bc2-0800200c9a66</cfClassId> <cfClassSchemeId>b7135ad0-1d00-11e1-8bc2-0800200c9a66</cfClassSchemeId> <cfStartDate>2010T24:00:00</cfStartDate> </cfPers_ResPubl> </cfResPubl> <cfPers> <cfPersId>ibn-Pers-755</cfPersId> <cfPersName_Pers> <cfPersNameId>ibn-PersName-755-3</cfPersNameId> <cfClassId>55f90543-d631-42eb-8d47-d8d9266cbb26</cfClassId> <cfClassSchemeId>7375609d-cfa6-45ce-a803-75de69abe21f</cfClassSchemeId> <cfStartDate>2010T24:00:00</cfStartDate> <cfFamilyNames>Амброс</cfFamilyNames> <cfFirstNames>Тудор</cfFirstNames> </cfPersName_Pers> </cfPers> <cfPers> <cfPersId>ibn-Pers-26483</cfPersId> <cfPersName_Pers> <cfPersNameId>ibn-PersName-26483-3</cfPersNameId> <cfClassId>55f90543-d631-42eb-8d47-d8d9266cbb26</cfClassId> <cfClassSchemeId>7375609d-cfa6-45ce-a803-75de69abe21f</cfClassSchemeId> <cfStartDate>2010T24:00:00</cfStartDate> <cfFamilyNames>Урсатий</cfFamilyNames> <cfFirstNames>Николай</cfFirstNames> </cfPersName_Pers> </cfPers> </CERIF>