Conţinutul numărului revistei |
Articolul precedent |
Articolul urmator |
![]() |
![]() ![]() |
Ultima descărcare din IBN: 2022-10-11 17:54 |
![]() ZAMOLODCHIKOV, R., STARKOV, Yu., DZHANTUKHANOVA, S., PITEL, Ecaterina, IBRAGIMOV, A., GULOVA, N.. Late results in the endoscopic treatment of cicatricial bile duct strictures. In: Annals of HPB Surgery, 2022, nr. 2(27), pp. 94-101. ISSN 1995-5464. DOI: https://doi.org/10.16931/1995-5464.2022-2-94-101 |
EXPORT metadate: Google Scholar Crossref CERIF DataCite Dublin Core |
Annals of HPB Surgery | ||||||
Numărul 2(27) / 2022 / ISSN 1995-5464 /ISSNe 2408-9524 | ||||||
|
||||||
DOI:https://doi.org/10.16931/1995-5464.2022-2-94-101 | ||||||
Pag. 94-101 | ||||||
|
||||||
![]() |
||||||
Rezumat | ||||||
Aim. To evaluate the late results of staged endoscopic treatment of patients with corrosive bile duct strictures. Materials and methods. The study included 41 patients with corrosive bile duct strictures varying in etiology and localization. The patients were observed over a seven-year period, most of whom had already undergone endoscopic treatment. Results. The technical success rate amounted to 100%. The procedure of staged stenting was completed in 34 out of 37 patients under observation. The clinical success rate, defined as the release of a stricture, reached 94%. In the postoperative period, the incidence of complications amounted to 8.8%. Only 2 out of 34 patients who had undergone stenting exhibited stricture recurrence. Conclusion. The staged placement of multiple plastic stents is characterized by high technical and clinical success rates while involving few complications, as well as a consistently low rate of stricture recurrence in the long-term period. |
||||||
Cuvinte-cheie bile ducts, complications, endoscopic treatment, late results, liver, stent, stenting, stricture, печень, желчные протоки, стриктура, эндоскопическое лечение, стентирование, стент, осложнения, отдалённые результаты |
||||||
|
DataCite XML Export
<?xml version='1.0' encoding='utf-8'?> <resource xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' xmlns='http://datacite.org/schema/kernel-3' xsi:schemaLocation='http://datacite.org/schema/kernel-3 http://schema.datacite.org/meta/kernel-3/metadata.xsd'> <identifier identifierType='DOI'>10.16931/1995-5464.2022-2-94-101</identifier> <creators> <creator> <creatorName>Zamolodchikov, R.D.</creatorName> <affiliation>Институт хирургии им. А.В. Вишневского, Rusia</affiliation> </creator> <creator> <creatorName>Starkov, Y.G.</creatorName> <affiliation>Институт хирургии им. А.В. Вишневского, Rusia</affiliation> </creator> <creator> <creatorName>Dzhantukhanova, S.V.</creatorName> <affiliation>Институт хирургии им. А.В. Вишневского, Rusia</affiliation> </creator> <creator> <creatorName>Pitel, E.</creatorName> <affiliation>Universitatea de Stat de Medicină şi Farmacie „Nicolae Testemiţanu“, Moldova, Republica</affiliation> </creator> <creator> <creatorName>Ibragimov, A.S.</creatorName> <affiliation>Институт хирургии им. А.В. Вишневского, Rusia</affiliation> </creator> <creator> <creatorName>Gulova, N.V.</creatorName> <affiliation>Институт хирургии им. А.В. Вишневского, Rusia</affiliation> </creator> </creators> <titles> <title xml:lang='en,ru'>Late results in the endoscopic treatment of cicatricial bile duct strictures</title> </titles> <publisher>Instrumentul Bibliometric National</publisher> <publicationYear>2022</publicationYear> <relatedIdentifier relatedIdentifierType='ISSN' relationType='IsPartOf'>1995-5464</relatedIdentifier> <subjects> <subject>bile ducts</subject> <subject>complications</subject> <subject>endoscopic treatment</subject> <subject>late results</subject> <subject>liver</subject> <subject>stent</subject> <subject>stenting</subject> <subject>stricture</subject> <subject>печень</subject> <subject>желчные протоки</subject> <subject>стриктура</subject> <subject>эндоскопическое лечение</subject> <subject>стентирование</subject> <subject>стент</subject> <subject>осложнения</subject> <subject>отдалённые результаты</subject> </subjects> <dates> <date dateType='Issued'>2022-06-20</date> </dates> <resourceType resourceTypeGeneral='Text'>Journal article</resourceType> <descriptions> <description xml:lang='en' descriptionType='Abstract'><p>Aim. To evaluate the late results of staged endoscopic treatment of patients with corrosive bile duct strictures. Materials and methods. The study included 41 patients with corrosive bile duct strictures varying in etiology and localization. The patients were observed over a seven-year period, most of whom had already undergone endoscopic treatment. Results. The technical success rate amounted to 100%. The procedure of staged stenting was completed in 34 out of 37 patients under observation. The clinical success rate, defined as the release of a stricture, reached 94%. In the postoperative period, the incidence of complications amounted to 8.8%. Only 2 out of 34 patients who had undergone stenting exhibited stricture recurrence. Conclusion. The staged placement of multiple plastic stents is characterized by high technical and clinical success rates while involving few complications, as well as a consistently low rate of stricture recurrence in the long-term period.</p></description> <description xml:lang='ru' descriptionType='Abstract'><p>Цель. Оценить отдаленные результаты этапного эндоскопического лечения пациентов с рубцовыми стриктурами желчных протоков. Материал и методы. В исследование включен 41 пациент с рубцовыми стриктурами желчных протоков различной этиологии и локализации. Исследование охватывает более чем семилетний период наблюдения за пациентами, у большинства из которых эндоскопическое лечение уже завершено. Результаты. Уровень технического успеха составил 100%. Этапное стентирование завершено у 34 из 37 находящихся под наблюдением пациентов. Уровень клинического успеха, определенный как разрешение стриктуры, достиг 94%. Частота осложнений в послеоперационном периоде составила 8,8%. Рецидив стриктуры развился только у 2 из 34 пациентов с завершенным стентированием. Заключение. Применение этапной установки множественных пластиковых стентов характеризуется не только высоким уровнем технического и клинического успеха при малом числе осложнений, но и стабильно малой частотой рецидива стриктур в отдаленном периоде.</p></description> </descriptions> <formats> <format>application/pdf</format> </formats> </resource>