Experimental setup for elemental analysis using prompt gamma rays at research reactor IBR-2
Închide
Articolul precedent
Articolul urmator
316 2
Ultima descărcare din IBN:
2023-03-14 16:03
Căutarea după subiecte
similare conform CZU
539.1+621.039.51 (1)
Fizică nucleară. Fizică atomică. Fizică moleculară (87)
Construcția de mașini în general. Tehnică nucleară. Electrotehnică. Tehnologie mecanică (1726)
SM ISO690:2012
HRAMCO, Constantin, BORZAKOV, Sergey, GUNDORIN, N. A., LYCHAGIN, E., TURLYBEKULY, K., NEHAEV, G., MUZYCHKA, A., STRELKOV, A., TEYMUROV, E.. Experimental setup for elemental analysis using prompt gamma rays at research reactor IBR-2. In: Ecological and environmental chemistry : - 2022, Ed. 7, 3-4 martie 2022, Chișinău. Chisinau: Centrul Editorial-Poligrafic al USM, 2022, Ediția 7, Vol.1, p. 211. ISBN 978-9975-159-07-4.. 10.19261/eec.2022.v1
EXPORT metadate:
Google Scholar
Crossref
CERIF

DataCite
Dublin Core
Ecological and environmental chemistry
Ediția 7, Vol.1, 2022
Conferința "Ecological and environmental chemistry 2022"
7, Chișinău, Moldova, 3-4 martie 2022

Experimental setup for elemental analysis using prompt gamma rays at research reactor IBR-2

CZU: 539.1+621.039.51

Pag. 211-211

Hramco Constantin12, Borzakov Sergey1, Gundorin N. A.1, Lychagin E.1, Turlybekuly K.134, Nehaev G.1, Muzychka A.1, Strelkov A.1, Teymurov E.156
 
1 Joint Institute of Nuclear Research,
2 Institute of Chemistry,
3 L.N. Gumilyov Eurasian National University,
4 Institute of Nuclear Physics, Ministry of Energy of the Republic of Kazakhstan,
5 National Research Nuclear University MEPhI, Moscow,
6 National Nuclear Research Centre, Azerbaijan
 
Proiecte:
 
Disponibil în IBN: 18 martie 2022


Rezumat

The new experimental setup has been built at the 11b channel of the IBR-2 research reactor at FLNP, JINR, to study the elemental composition of samples by registration of prompt gamma emission during thermal neutron capture. The setup consists of a curved mirror neutron guide and a radiation-resistant HPGe high-purity germanium detector. The detector is surrounded by lead shielding to suppress natural background gamma level. The sample is placed in a vacuum channel and surrounded by a LiF shield to suppress the gamma background generated by scattered neutrons. This work presents characteristics of the experimental setup. An example of hydrogen concentration determining in diamond powder made by detonation synthesis is given and on its basis, the sensitivity of the setup is calculated being ~10μg.