Measurement of Biokinetic Parameters with the CvMob Program at the Level of the Lower Limb with a Functional 3D Printed Knee Orthosis
Închide
Articolul precedent
Articolul urmator
179 1
Ultima descărcare din IBN:
2023-12-05 00:17
SM ISO690:2012
TULICĂ, Alexandru-Constantin, ROȘCA, Ileana Constanţa, DRUGĂ, Corneliu-Nicolae, ȘERBAN, Ionel. Measurement of Biokinetic Parameters with the CvMob Program at the Level of the Lower Limb with a Functional 3D Printed Knee Orthosis. In: IFMBE Proceedings: Nanotechnologies and Biomedical Engineering, Ed. 6, 20-23 septembrie 2023, Chişinău. Chişinău: Springer Science and Business Media Deutschland GmbH, 2023, Ediția 6, p. 118. ISBN 978-9975-72-773-0..
EXPORT metadate:
Google Scholar
Crossref
CERIF

DataCite
Dublin Core
IFMBE Proceedings
Ediția 6, 2023
Conferința "6th International Conference on Nanotechnologies and Biomedical Engineering"
6, Chişinău, Moldova, 20-23 septembrie 2023

Measurement of Biokinetic Parameters with the CvMob Program at the Level of the Lower Limb with a Functional 3D Printed Knee Orthosis


Pag. 118-118

Tulică Alexandru-Constantin, Roșca Ileana Constanţa, Drugă Corneliu-Nicolae, Șerban Ionel
 
Transilvania University of Brașov
 
 
Disponibil în IBN: 13 octombrie 2023


Rezumat

The aim of this research is to evaluate the kinematic parameters, velocity and acceleration at the knee joint during flexion and extension using a functional 3D printed knee brace. For this purpose, the Contemplas system was used together with the CvMob program to record and analyze knee movements in real time. The subject wore a functional knee brace that was activated at an angle of 30 degrees. The Contemplas system recorded images of the knee motion during flexion and extension, and the CvMob program was used to analyze the kinematic parameters through discrete graphics. The obtained results revealed significant changes in the kinematic parameters of the knee during the use of the functional knee orthosis. The velocity of knee flexion and extension was assessed and plotted in distinct graphs, highlighting changes in knee joint motion. Acceleration was also measured and analyzed in the context of orthosis use. The Contemplas system and the CvMob program provided an efficient way to record and analyze knee movements, allowing a detailed assessment of knee joint performance. This research demonstrates the importance of using the functional 3D printed knee orthosis, together with the Contemplas system and the CvMob program, in assessing and improving kinematic parameters, velocity and acceleration at the knee joint. These results can be applied in the development of personalized rehabilitation and therapy strategies for patients with knee conditions and injuries, with the aim of improving the functionality and mobility of the joint.