BJELICA, Bojan, ZELENOVIC, Milan, PRZULJ, Radomir, AKSOVIC, Nikola, PAN-TELIC, Sasa, BUBANJ, Sasa R., KULUNDZIC, Dejan, ALEXE, Cristina Ioana, CIOCAN, Vasile Catalin, ALEXE, Dan Iulian, SETIAWAN, Edi, LUNGU, Ecaterina. Effect of hyperbaric chamber on saturation and heart frequency. In: Balneo and PRM Research Journal, 2023, vol. 14, pp. 1-9. ISSN 2734-844X. DOI: https://doi.org/10.12680/balneo.2023.601
EXPORT metadate:
Google Scholar
Crossref
CERIF

DataCite
Dublin Core
Balneo and PRM Research Journal
Volumul 14 / 2023 / ISSN 2734-844X /ISSNe 2734-8458

Effect of hyperbaric chamber on saturation and heart frequency

DOI:https://doi.org/10.12680/balneo.2023.601

Pag. 1-9

Bjelica Bojan1, Zelenovic Milan1, Przulj Radomir1, Aksovic Nikola2, Pan-Telic Sasa3, Bubanj Sasa R.3, Kulundzic Dejan4, Alexe Cristina Ioana5, Ciocan Vasile Catalin5, Alexe Dan Iulian5, Setiawan Edi6, Lungu Ecaterina78
 
1 University of East Sarajevo,
2 University of Pristina,
3 University of Nis,
4 Primary school "Bratstvo", Novi Pazar,
5 "Vasile Alecsandri" University of Bacau,
6 Suryakancana University, Cianjur,
7 "Dunarea de Jos" University of Galati,
8 State University of Physical Education and Sport
 
 
Disponibil în IBN: 15 martie 2024


Rezumat

Introduction: (1) Background: The use of oxygen under pressure greater than atmospheric represents progress that can be measured in terms of importance with the introduction of blood transfusion and antibiotics in therapy. The aim of the research was to determine the impact of using a hyperbaric chamber (HC) on muscle, arterial saturation and heart rate.; (2) Methods: Twelve respondents who engaged in recreational exercise. HC Macy Pan O2 801 was used for oxygen delivery. Muscle saturation was assessed with the IDIAG Moxy device. Arterial saturation was monitored with an Omron OM-35 device, and intraventricular heart rate with a Polar FT2 device. All parameters were monitored before and after HC treatment for 50 min. and constant pressure of 2.5 ATA.; (3) Results: There was a significant increase in saturation in the pectoralis, (+8.99%) p=.038, hamstring (+8.62%) p=.042. In capillary saturation (+1.42%) p=.008. Heart rate was reduced on average by about 8.5 beats p=.003. In the region of the latissimus do not record a statistically significant change in oxygen (+6.64%) p=060, however, numerical differences were determined.; (4) Conclusions: HC is an effective means of achieving positive physiological effects. It needs to be determined whether a higher ATA or duration of treatment gives better effects.

Cuvinte-cheie
Heart rate, IDIAG, MacyPan, Moxy, Muscle, oxygen