SM ISO690:2012 PURECE, Cristian, CHERNIKA, Ion, DUMITRESCU, Sorin-Adrian. Improvement of measurements for the assessment of operational efficiency of the hydropower plants. In: ISH Journal of Hydraulic Engineering, 2016, nr. 2(22), pp. 142-147. ISSN 0971-5010. DOI: https://doi.org/10.1080/09715010.2015.1103200 |
EXPORT metadate: Google Scholar Crossref CERIF DataCite Dublin Core |
ISH Journal of Hydraulic Engineering | ||||||
Numărul 2(22) / 2016 / ISSN 0971-5010 /ISSNe 2165-3040 | ||||||
|
||||||
DOI:https://doi.org/10.1080/09715010.2015.1103200 | ||||||
Pag. 142-147 | ||||||
|
||||||
Rezumat | ||||||
The article aims at improving the techniques used for assessing the discharge of a hydropower plant by means of discharge measurements using current meters located on a mobile frame. The mobile frame can modify the angle between the current meter axis and the local velocity vector, thus reducing the discharge calculation error and improving assessing accuracy. The improvement in the discharge measuring accuracy also increases the accurate determination of the optimum operating range and the maximum efficiency of the hydropower plant units. |
||||||
Cuvinte-cheie current meter, Discharge Measurement, efficiency, Mobile frame, velocity |
||||||
|