Articolul precedent |
Articolul urmator |
![]() |
![]() ![]() |
![]() OLESCHUK, Valentin, VASILIEV, Irina. Motor Drive System with Double-Delta-Sourced Stator Winding and Two Modulated NPC Converters. In: IEEE KhPI Week on Advanced Technology: KhPI Week 2020, 5-10 octombrie 2020, Kharkiv. New Jersey, SUA: Institute of Electrical and Electronics Engineers Inc., 2020, pp. 357-362. ISBN 978-073814236-4. DOI: https://doi.org/10.1109/KhPIWeek51551.2020.9250100 |
EXPORT metadate: Google Scholar Crossref CERIF DataCite Dublin Core |
IEEE KhPI Week on Advanced Technology 2020 | ||||||
Conferința "IEEE KhPI Week on Advanced Technology" Kharkiv, Ucraina, 5-10 octombrie 2020 | ||||||
|
||||||
DOI:https://doi.org/10.1109/KhPIWeek51551.2020.9250100 | ||||||
Pag. 357-362 | ||||||
|
||||||
Vezi articolul | ||||||
Rezumat | ||||||
In this paper, method of multi-zone pulsewidth modulation (PWM) has been disseminated for wide-range adjustment of two neutral-clamped converters of double-delta-sourced winding system, which is perspective for application in high power adjustable speed drives with dual-stator-winding motor. In this case, stator winding voltage of system is characterized by symmetries, with the lacking in its spectra of even-order voltage harmonics and sub-harmonics. Also, specific control scheme used for regulation of two inverters assures both elimination of common-mode voltage (CMV), and balanced neutral-point voltage of converters of this installation. Numerical simulations have been executed for systems regulated by three basic versions of synchronous multi-zone pulsewidth modulation. |
||||||
Cuvinte-cheie inverter, motor drive, PWM, voltage spectra |
||||||
|
Cerif XML Export
<?xml version='1.0' encoding='utf-8'?> <CERIF xmlns='urn:xmlns:org:eurocris:cerif-1.5-1' xsi:schemaLocation='urn:xmlns:org:eurocris:cerif-1.5-1 http://www.eurocris.org/Uploads/Web%20pages/CERIF-1.5/CERIF_1.5_1.xsd' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' release='1.5' date='2012-10-07' sourceDatabase='Output Profile'> <cfResPubl> <cfResPublId>ibn-ResPubl-118159</cfResPublId> <cfResPublDate>2020</cfResPublDate> <cfStartPage>357</cfStartPage> <cfISBN>978-073814236-4</cfISBN> <cfURI>https://ibn.idsi.md/ro/vizualizare_articol/118159</cfURI> <cfTitle cfLangCode='EN' cfTrans='o'>Motor Drive System with Double-Delta-Sourced Stator Winding and Two Modulated NPC Converters</cfTitle> <cfKeyw cfLangCode='EN' cfTrans='o'>inverter; motor drive; PWM; voltage spectra</cfKeyw> <cfAbstr cfLangCode='EN' cfTrans='o'><p>In this paper, method of multi-zone pulsewidth modulation (PWM) has been disseminated for wide-range adjustment of two neutral-clamped converters of double-delta-sourced winding system, which is perspective for application in high power adjustable speed drives with dual-stator-winding motor. In this case, stator winding voltage of system is characterized by symmetries, with the lacking in its spectra of even-order voltage harmonics and sub-harmonics. Also, specific control scheme used for regulation of two inverters assures both elimination of common-mode voltage (CMV), and balanced neutral-point voltage of converters of this installation. Numerical simulations have been executed for systems regulated by three basic versions of synchronous multi-zone pulsewidth modulation.</p></cfAbstr> <cfResPubl_Class> <cfClassId>eda2d9e9-34c5-11e1-b86c-0800200c9a66</cfClassId> <cfClassSchemeId>759af938-34ae-11e1-b86c-0800200c9a66</cfClassSchemeId> <cfStartDate>2020T24:00:00</cfStartDate> </cfResPubl_Class> <cfResPubl_Class> <cfClassId>e601872f-4b7e-4d88-929f-7df027b226c9</cfClassId> <cfClassSchemeId>40e90e2f-446d-460a-98e5-5dce57550c48</cfClassSchemeId> <cfStartDate>2020T24:00:00</cfStartDate> </cfResPubl_Class> <cfPers_ResPubl> <cfPersId>ibn-person-677</cfPersId> <cfClassId>49815870-1cfe-11e1-8bc2-0800200c9a66</cfClassId> <cfClassSchemeId>b7135ad0-1d00-11e1-8bc2-0800200c9a66</cfClassSchemeId> <cfStartDate>2020T24:00:00</cfStartDate> </cfPers_ResPubl> <cfPers_ResPubl> <cfPersId>ibn-person-72968</cfPersId> <cfClassId>49815870-1cfe-11e1-8bc2-0800200c9a66</cfClassId> <cfClassSchemeId>b7135ad0-1d00-11e1-8bc2-0800200c9a66</cfClassSchemeId> <cfStartDate>2020T24:00:00</cfStartDate> </cfPers_ResPubl> </cfResPubl> <cfPers> <cfPersId>ibn-Pers-677</cfPersId> <cfPersName_Pers> <cfPersNameId>ibn-PersName-677-3</cfPersNameId> <cfClassId>55f90543-d631-42eb-8d47-d8d9266cbb26</cfClassId> <cfClassSchemeId>7375609d-cfa6-45ce-a803-75de69abe21f</cfClassSchemeId> <cfStartDate>2020T24:00:00</cfStartDate> <cfFamilyNames>Oleschuk</cfFamilyNames> <cfFirstNames>Valentin</cfFirstNames> <cfFamilyNames>Олещук</cfFamilyNames> <cfFirstNames>Валентин</cfFirstNames> </cfPersName_Pers> </cfPers> <cfPers> <cfPersId>ibn-Pers-72968</cfPersId> <cfPersName_Pers> <cfPersNameId>ibn-PersName-72968-3</cfPersNameId> <cfClassId>55f90543-d631-42eb-8d47-d8d9266cbb26</cfClassId> <cfClassSchemeId>7375609d-cfa6-45ce-a803-75de69abe21f</cfClassSchemeId> <cfStartDate>2020T24:00:00</cfStartDate> <cfFamilyNames>Vasiliev</cfFamilyNames> <cfFirstNames>Irina</cfFirstNames> <cfFamilyNames>Васильева</cfFamilyNames> <cfFirstNames>Ирина</cfFirstNames> </cfPersName_Pers> </cfPers> </CERIF>