Motor Drive System with Double-Delta-Sourced Stator Winding and Two Modulated NPC Converters
Close
Articolul precedent
Articolul urmator
532 0
SM ISO690:2012
OLESCHUK, Valentin, VASILIEV, Irina. Motor Drive System with Double-Delta-Sourced Stator Winding and Two Modulated NPC Converters. In: IEEE KhPI Week on Advanced Technology: KhPI Week 2020, 5-10 octombrie 2020, Kharkiv. New Jersey, SUA: Institute of Electrical and Electronics Engineers Inc., 2020, pp. 357-362. ISBN 978-073814236-4. DOI: https://doi.org/10.1109/KhPIWeek51551.2020.9250100
EXPORT metadate:
Google Scholar
Crossref
CERIF

DataCite
Dublin Core
IEEE KhPI Week on Advanced Technology 2020
Conferința "IEEE KhPI Week on Advanced Technology"
Kharkiv, Ucraina, 5-10 octombrie 2020

Motor Drive System with Double-Delta-Sourced Stator Winding and Two Modulated NPC Converters

DOI:https://doi.org/10.1109/KhPIWeek51551.2020.9250100

Pag. 357-362

Oleschuk Valentin, Vasiliev Irina
 
Institute of Power Engineering
 
 
Disponibil în IBN: 30 decembrie 2020


Rezumat

In this paper, method of multi-zone pulsewidth modulation (PWM) has been disseminated for wide-range adjustment of two neutral-clamped converters of double-delta-sourced winding system, which is perspective for application in high power adjustable speed drives with dual-stator-winding motor. In this case, stator winding voltage of system is characterized by symmetries, with the lacking in its spectra of even-order voltage harmonics and sub-harmonics. Also, specific control scheme used for regulation of two inverters assures both elimination of common-mode voltage (CMV), and balanced neutral-point voltage of converters of this installation. Numerical simulations have been executed for systems regulated by three basic versions of synchronous multi-zone pulsewidth modulation.

Cuvinte-cheie
inverter, motor drive, PWM, voltage spectra

Cerif XML Export

<?xml version='1.0' encoding='utf-8'?>
<CERIF xmlns='urn:xmlns:org:eurocris:cerif-1.5-1' xsi:schemaLocation='urn:xmlns:org:eurocris:cerif-1.5-1 http://www.eurocris.org/Uploads/Web%20pages/CERIF-1.5/CERIF_1.5_1.xsd' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' release='1.5' date='2012-10-07' sourceDatabase='Output Profile'>
<cfResPubl>
<cfResPublId>ibn-ResPubl-118159</cfResPublId>
<cfResPublDate>2020</cfResPublDate>
<cfStartPage>357</cfStartPage>
<cfISBN>978-073814236-4</cfISBN>
<cfURI>https://ibn.idsi.md/ro/vizualizare_articol/118159</cfURI>
<cfTitle cfLangCode='EN' cfTrans='o'>Motor Drive System with Double-Delta-Sourced Stator Winding and Two Modulated NPC Converters</cfTitle>
<cfKeyw cfLangCode='EN' cfTrans='o'>inverter; motor drive; PWM; voltage spectra</cfKeyw>
<cfAbstr cfLangCode='EN' cfTrans='o'><p>In this paper, method of multi-zone pulsewidth modulation (PWM) has been disseminated for wide-range adjustment of two neutral-clamped converters of double-delta-sourced winding system, which is perspective for application in high power adjustable speed drives with dual-stator-winding motor. In this case, stator winding voltage of system is characterized by symmetries, with the lacking in its spectra of even-order voltage harmonics and sub-harmonics. Also, specific control scheme used for regulation of two inverters assures both elimination of common-mode voltage (CMV), and balanced neutral-point voltage of converters of this installation. Numerical simulations have been executed for systems regulated by three basic versions of synchronous multi-zone pulsewidth modulation.</p></cfAbstr>
<cfResPubl_Class>
<cfClassId>eda2d9e9-34c5-11e1-b86c-0800200c9a66</cfClassId>
<cfClassSchemeId>759af938-34ae-11e1-b86c-0800200c9a66</cfClassSchemeId>
<cfStartDate>2020T24:00:00</cfStartDate>
</cfResPubl_Class>
<cfResPubl_Class>
<cfClassId>e601872f-4b7e-4d88-929f-7df027b226c9</cfClassId>
<cfClassSchemeId>40e90e2f-446d-460a-98e5-5dce57550c48</cfClassSchemeId>
<cfStartDate>2020T24:00:00</cfStartDate>
</cfResPubl_Class>
<cfPers_ResPubl>
<cfPersId>ibn-person-677</cfPersId>
<cfClassId>49815870-1cfe-11e1-8bc2-0800200c9a66</cfClassId>
<cfClassSchemeId>b7135ad0-1d00-11e1-8bc2-0800200c9a66</cfClassSchemeId>
<cfStartDate>2020T24:00:00</cfStartDate>
</cfPers_ResPubl>
<cfPers_ResPubl>
<cfPersId>ibn-person-72968</cfPersId>
<cfClassId>49815870-1cfe-11e1-8bc2-0800200c9a66</cfClassId>
<cfClassSchemeId>b7135ad0-1d00-11e1-8bc2-0800200c9a66</cfClassSchemeId>
<cfStartDate>2020T24:00:00</cfStartDate>
</cfPers_ResPubl>
</cfResPubl>
<cfPers>
<cfPersId>ibn-Pers-677</cfPersId>
<cfPersName_Pers>
<cfPersNameId>ibn-PersName-677-3</cfPersNameId>
<cfClassId>55f90543-d631-42eb-8d47-d8d9266cbb26</cfClassId>
<cfClassSchemeId>7375609d-cfa6-45ce-a803-75de69abe21f</cfClassSchemeId>
<cfStartDate>2020T24:00:00</cfStartDate>
<cfFamilyNames>Oleschuk</cfFamilyNames>
<cfFirstNames>Valentin</cfFirstNames>
<cfFamilyNames>Олещук</cfFamilyNames>
<cfFirstNames>Валентин</cfFirstNames>
</cfPersName_Pers>
</cfPers>
<cfPers>
<cfPersId>ibn-Pers-72968</cfPersId>
<cfPersName_Pers>
<cfPersNameId>ibn-PersName-72968-3</cfPersNameId>
<cfClassId>55f90543-d631-42eb-8d47-d8d9266cbb26</cfClassId>
<cfClassSchemeId>7375609d-cfa6-45ce-a803-75de69abe21f</cfClassSchemeId>
<cfStartDate>2020T24:00:00</cfStartDate>
<cfFamilyNames>Vasiliev</cfFamilyNames>
<cfFirstNames>Irina</cfFirstNames>
<cfFamilyNames>Васильева</cfFamilyNames>
<cfFirstNames>Ирина</cfFirstNames>
</cfPersName_Pers>
</cfPers>
</CERIF>