Angiotensin 1-7 blunts in vitro induced acute heart failure
Закрыть
Conţinutul numărului revistei
Articolul precedent
Articolul urmator
110 0
SM ISO690:2012
KOBETS, Valery, TACU, Lilia, COBET, E., ROTARU, Victor, CIOBANU, Lucia, ROTARU, Adrian. Angiotensin 1-7 blunts in vitro induced acute heart failure. In: European Journal of Heart Failure, 2017, vol. 19, supl. nr. 1, p. 597. ISSN 1388-9842.
EXPORT metadate:
Google Scholar
Crossref
CERIF

DataCite
Dublin Core
European Journal of Heart Failure
Volumul 19, Supliment nr. 1 / 2017 / ISSN 1388-9842 /ISSNe 1879-0844

Angiotensin 1-7 blunts in vitro induced acute heart failure


Pag. 597-597

Kobets Valery1, Tacu Lilia1, Cobet E.2, Rotaru Victor1, Ciobanu Lucia3, Rotaru Adrian4
 
1 ”Nicolae Testemițanu” State University of Medicine and Pharmacy,
2 Moldova State University,
3 Institute of Cardiology,
4 Harvard Medical School, Boston
 
 
Disponibil în IBN: 4 aprilie 2024


Rezumat

Background: Angiotensin 1-7 (Ang 1-7) comprises consistent evidences regarding cardiovascular regulatory benefits due to Ang II receptor AT1 modulation via mass receptor. Aim: Evaluation of the Ang 1-7 cardiac effects in the in vitro induced acute heart failure. Material and methods: Acute heart failure (AHF) was induced using the model of isolated rat pumping heart perfused by Krebs solution without glucose during 20 min according to Neely-Rovetto model (glucose is a single energetic substrate in this model) – control series. In another series heart has been perfused without glucose, but Ang 1-7 was added till final c oncentration o f 1 0-7 M– medicated series. Left ventricle (LV) functional parameters were assayed during inotropic stimulation by norepinephrine (NE) and endothelin 1 (ET-1) in concentration of 10-6 M, or ischemia-reperfusion impact (15 min of total ischemia followed by 20 min of reperfusion) reproduced in Langendorff isovolumic isolated heart. Results: Cardiac output (CO) significantly decreased after 20 min perfusion of isolate heart without glucose by 25,9% (29,4 ± 1,3 vs 39,7 ± 2,1 ml/min). Action of Ang 1-7 led to a less decline of CO compared to control (34,8 ± 1,6 vs 29,4 ± 1,3 ml/min, p < 0,05). NE stimulation induced an increase of control CO by 10,7% associated by LV end-diastolic pressure (LVEDP) elevation of 30,3% while in medicated series response was better: CO increased by 14,4% and LVEDP boosted only by 17,6% ((19,3 ± 1,6 (Ang 1-7) vs 27,4 ± 1,7 (control) mm Hg, p < 0,05). Stimulated by ET-1 control isolated heart responded by a negative inotropic effect, and both systolic LV pressure and CO fallen respectively by 13,2% and 9,6%. Ang 1-7 insured a positive inotropic response during ET-1 action leading to CO and LV systolic pressure increase respectively by 10,5% and 11,7%. Ang 1-7 also improved the dynamics of LVEDP during ischemia-reperfusion. Thus, LVEDP was in medicated series significantly less than control index at finish of both ischemia (41,3 ± 3,2 vs 55,4 ± 4,4 mm Hg) and reperfusion (17,2 ± 1,4 vs 28,7 ± 2,2 mm Hg) periods. Conclusion: Angiotensin 1-7 is a component of renin-angiotensin-aldosterone system which has a benefic action on acutely developing heart failure due to energy privation, manifested by improvement of inotropic response of NE and reinstated positive inotropic of ET-1 action as well as significant diminution of LVEDP during ischemia-reperfusion syndrome.

Crossref XML Export

<?xml version='1.0' encoding='utf-8'?>
<doi_batch version='4.3.7' xmlns='http://www.crossref.org/schema/4.3.7' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' xsi:schemaLocation='http://www.crossref.org/schema/4.3.7 http://www.crossref.org/schema/deposit/crossref4.3.7.xsd'>
<head>
<doi_batch_id>ibn-201057</doi_batch_id>
<timestamp>1719770248</timestamp>
<depositor>
<depositor_name>Information Society Development Instiute, Republic of Moldova</depositor_name>
<email_address>[email protected]</email_address>
</depositor>
</head>
<body>
<journal>
<journal_metadata>
<full_title>European Journal of Heart Failure</full_title>
<issn media_type='print'>13889842</issn>
</journal_metadata>
<journal_issue>
<publication_date media_type='print'>
<year>2017</year>
</publication_date>
<issue></issue>
</journal_issue>
<journal_article publication_type='full_text'><titles>
<title>Angiotensin 1-7 blunts in vitro induced acute heart failure</title>
</titles>
<contributors>
<person_name sequence='first' contributor_role='author'>
<given_name>Valeriu</given_name>
<surname>Cobeţ</surname>
</person_name>
<person_name sequence='additional' contributor_role='author'>
<given_name>Lilia</given_name>
<surname>Tacu</surname>
</person_name>
<person_name sequence='additional' contributor_role='author'>
<given_name>E.</given_name>
<surname>Cobet</surname>
</person_name>
<person_name sequence='additional' contributor_role='author'>
<given_name>Victor</given_name>
<surname>Rotaru</surname>
</person_name>
<person_name sequence='additional' contributor_role='author'>
<given_name>Lucia</given_name>
<surname>Ciobanu</surname>
</person_name>
<person_name sequence='additional' contributor_role='author'>
<given_name>Adrian</given_name>
<surname>Rotaru</surname>
</person_name>
</contributors>
<publication_date media_type='print'>
<year>2017</year>
</publication_date>
<pages>
<first_page>597</first_page>
<last_page>597</last_page>
</pages>
</journal_article>
</journal>
</body>
</doi_batch>