Dual-energy Computed Tomography gemstone spectral imaging: new horizons in visualization and differentiation of kidney stones composition
Închide
Conţinutul numărului revistei
Articolul precedent
Articolul urmator
16 0
Căutarea după subiecte
similare conform CZU
616.613-003.7-073.756.8 (1)
Patologia sistemului urogenital. Boli urinare şi sexuale (genitale) (412)
SM ISO690:2012
CONDREA, Silviu, ERŞOV, Sergiu, BALABCHINA, Anna, SAPTEFRATI, Xenia. Dual-energy Computed Tomography gemstone spectral imaging: new horizons in visualization and differentiation of kidney stones composition. In: Moldovan Medical Journal, 2018, nr. 61(S_RMI), p. 63. ISSN 2537-6373.
EXPORT metadate:
Google Scholar
Crossref
CERIF

DataCite
Dublin Core
Moldovan Medical Journal
Numărul 61(S_RMI) / 2018 / ISSN 2537-6373 /ISSNe 2537-6381

Dual-energy Computed Tomography gemstone spectral imaging: new horizons in visualization and differentiation of kidney stones composition

CZU: 616.613-003.7-073.756.8

Pag. 63-63

Condrea Silviu, Erşov Sergiu, Balabchina Anna, Saptefrati Xenia
 
Republican Center of Medical Diagnosis
 
 
Disponibil în IBN: 20 mai 2024


Rezumat

Background: Optimization of viewing tools and understanding the chemical composition of renal calculi become essential for choosing the best treatment strategy. In this study we aimed to assess the localization and chemical composition of renal stones using gemstone spectral imaging (GSI) color map mode on a single-source dual-energy computed tomography (CT). Material and methods: A total of 45 urinary stones with an unknown chemical composition were imaged with a dual-energy CT scanner using special scanning protocols with different combinations of tube voltage and conventional polychromatic imaging. The mean attenuation value (in Hounsfield units) of each stone was recorded on both low- and high-energy CT images for each protocol. The dual-energy CT ratio of the mean attenuation value of each stone was computed for each protocol. The difference between the CT numbers obtained was compared among the stone groups. Results: The obtained data enabled us to classify the urinary stones into 3 main groups: uric acid (n = 11), oxalate (n = 24) and phosphate (n = 10) stones. The estimated sensitivity and specificity of dual-energy CT for detecting uric acid stones was 98.0 and 99.2%, calcium stones – 95.1% and 97%; and mixed stones – 93.0% and 94.5% accordingly. Conclusions: Single-source dual-energy CT with GSI represents a perspective modality for evaluating the characteristics and chemical composition of urinary stones. The CT results were consistent with the spectral data, suggesting that spectral CT imaging techniques can be accurately used to improve the stone differentiation capability of dual-energy CT imaging.

Cuvinte-cheie
dual-energy CT, kidney stones, spectrum optimization