SM ISO690:2012 MOSTOVEI, Mihail, SOLOMON, Oleg, CHELE, Nicolae, MOSTOVEI, Andrei, FACHIRA, Andrei. Utilizarea electromiografiei de suprafață în ajustarea restaurărilor totale fixe cu suport implantar . In: Congresul consacrat aniversării a 75-a de la fondarea Universității de Stat de Medicină şi Farmacie „Nicolae Testemiţanu”, 21-23 octombrie 2020, Chişinău. Chişinău: USMF, 2020, p. 715. |
EXPORT metadate: Google Scholar Crossref CERIF DataCite Dublin Core |
Congresul consacrat aniversării a 75-a de la fondarea Universității de Stat de Medicină şi Farmacie „Nicolae Testemiţanu” 2020 | ||||||
Congresul "Congresul consacrat aniversării a 75-a de la fondarea Universității de Stat de Medicină şi Farmacie „Nicolae Testemiţanu”" Chişinău, Moldova, 21-23 octombrie 2020 | ||||||
|
||||||
Pag. 715-715 | ||||||
|
||||||
Descarcă PDF | ||||||
Rezumat | ||||||
Background. The static and dynamic controls of mechanoreceptors in dentate patients strongly differ from the ones with full implant restorations. The surface electromyography can serve as a control element during the or after the dental treatment. Objective of the study. Evaluation of surface electromyography indexes during the adjustment and delivery of fixed full implant supported restorations. Material and Methods. The study included 13 completely edentulous patients aged between 38 and 68 years old (55.76 ±2.62 years). Ten parameters were assessed during the electromyography: TAL, TAM, MMR, MML, PocTA, PocTL, BAR, IMPACT, ASYM, TORS comparing with the conventional method of occlusal adjustment during prostheses fixation. Results. In seven patients the clinical occlusal adjustments coincided with the parameters provided by the software presenting symmetrical muscular function. High values above 50μV, were recorded in 5 muscles (left temporalis 2 cases, right temporalis 3 cases, left masseter 3 cases, right masseter 2 cases). Three cases presented clinically acceptable symmetry of muscle function. In 3 cases out of 13 was not possible to equilibrate the muscular function despite the clinically adjusted prostheses. Conclusion. There are multiple factors that can influence the results of surface electromyography giving different values even in same patients. Thus, this method must not replace but complete the conventional occlusal adjustment procedures providing additional information. |
||||||
Cuvinte-cheie electromyography, implant-prosthetic treatment, occlusal adjustment, electromiografie, tratament implanto-protetic, ajustare ocluzală |
||||||
|