Эффективность использования встроенных пучков конденсаторов теплофикационных турбин для подогрева подпиточной воды
Închide
Conţinutul numărului revistei
Articolul precedent
Articolul urmator
1014 7
Ultima descărcare din IBN:
2022-12-12 14:13
Căutarea după subiecte
similare conform CZU
621.311 (218)
Electrotehnică (1154)
SM ISO690:2012
ШЕМПЕЛЕВ, Александр, СУВОРОВ, Дмитрий, ИГЛИН, Павел. Эффективность использования встроенных пучков конденсаторов теплофикационных турбин для подогрева подпиточной воды. In: Problemele Energeticii Regionale, 2018, nr. 3(38), pp. 36-51. ISSN 1857-0070. DOI: https://doi.org/10.5281/zenodo.2222335
EXPORT metadate:
Google Scholar
Crossref
CERIF

DataCite
Dublin Core
Problemele Energeticii Regionale
Numărul 3(38) / 2018 / ISSN 1857-0070

Эффективность использования встроенных пучков конденсаторов теплофикационных турбин для подогрева подпиточной воды

Efficiency of Using Built-In Bundles of Cogeneration Steam Turbine Condensers for Make-up Water Heating

Eficiența utilizării grinzilor integrate de condensare a turbinelor de cogenerare pentru încălzirea apei de adaos

DOI:https://doi.org/10.5281/zenodo.2222335
CZU: 621.311

Pag. 36-51

Шемпелев Александр, Суворов Дмитрий, Иглин Павел
 
Вятский государственный университет
 
 
Disponibil în IBN: 28 decembrie 2018


Rezumat

Целью работы является определение условий и эффективности использования встроенных пучков конденсаторов теплофикационных турбин для подогрева подпиточной воды при их работе с отключенными основными пучками. Для ее достижения использованы предложенная методика оценки величин тепловых потоков, поступающих в конденсатор, при работе с закрытой регулирующей диафрагмой ЧНД, разработанная авторами программа теплового расчета конденсаторов паровых турбин и расчетная математическая модель турбоустановки типа Т-50-130. Проведены расчеты количества теплоты, поступающей в конденсатор, в широком диапазоне расходов подпиточной воды и различных ее температурах на входе в зависимости от давления в нижнем теплофикационном отборе при нескольких уровнях пропускной способности закрытой регулирующей диафрагмы части низкого давления. Важным результатом расчетов является выявление существенных ограничений применимости данного способа подогрева подпиточной воды по условию непревышения температуры подпиточной воды на выходе из встроенного пучка. Проведены расчетные исследования на математической модели конденсатора по определению давления в конденсаторе в зависимости от давления в нижнем теплофикационном отборе при различных пропускных способностях регулирующей диафрагмы и различных расходах подпиточной воды. Еще одним существенным результатом является расчетная оценка энергетической эффективности при использовании встроенных пучков для подогрева подпиточной воды в конденсаторе при работе его с отключенными основными пучками в различных режимах работы. Значимость этих исследований состоит в том, что впервые рассчитана зависимость экономии теплоты турбоустановки от различных факторов. При этом установлено, что экономия теплоты в рассмотренных режимах всегда имеет место, причем при работе по тепловому графику она близка к величине тепловой нагрузки встроенных пучков конденсатора, а при работе по электрическому графику она в несколько раз ниже

The purpose of the study is to determine the conditions and efficiency of the use of built-in bundles of condensers of cogeneration steam turbines for make-up water heating during their work when the main bundles are disabled. The proposed method for estimating the heat flows entering the condenser when working with a closed sliding grid is used. The program of the thermal calculation program for steam turbine condensers and a computational mathematical model of a turbine plant type T-50-130 are applied. The heat fluxes entering the condenser were calculated in a wide range of influencing factors. An important result of the calculations is the identification of significant limitations of the applicability of this method of the make-up water heating according to the condition that the temperature of the make-up water at the exit from the built-in bundle is not exceeded. Calculation studies on the mathematical model of a condenser to determine the pressure in the condenser depending on the pressure in the lower heat extraction section with different levels of throughput of the closed sliding grid and different flow rates of the make-up water were carried out. Another result is a calculated estimate of the energy efficiency when using built-in bundles for heating the make-up water. It was found that heat saving in the considered modes always takes place, and when working on a heat mode, it is close to the heat load of the built-in bundles, and when working on an electric mode, it is several times lower.

Scopul lucrării este de a determina condițiile și eficiența utilizării grinzilor integrate a condensatoarelor turbinelor pentru încălzirea apei de adaos în timpul lucrului lor cu grinzile principale decuplate. În acest scop se utilizează metodologia propusă pentru estimarea fluxurilor de căldură, care intră în condensator, atunci când se lucrează cu o diafragmă de reglare închisă a unui PND cu ajutorul unui program pentru calculul termic al condensatoarelor cu turbină cu aburi și al modelului matematic computațional al turbinei tip T-50-130. Cantitatea de căldură care intră în condensator a fost calculată într-o gamă largă de consum a apei de adaos și pentru diferite temperaturi a apei la intrare, în funcție de presiunea în priza inferioară de cedare a căldură pentru mai multe paliere de transfer în caz că diafragma de reglare a circuitului de presiune joasă este închisă. Un alt rezultat semnificativ este estimarea calculată a eficienței energetice la utilizarea fasciculelor înglobate pentru încălzirea apei de adaos în condensator în regimul când grinzile principale sunt decuplate. Semnificația acestor studii constă în faptul că pentru prima dată s-a calculat dependența economiei de căldură a unei instalații cu turbină în funcție de diverși factori. S-a constatat că economisirea de căldură în regimurile luate în considerare are loc întotdeauna, iar atunci când se lucrează în corespundere cu curba de sarcină a energiei termice, valoarea acestei economii este apropiată de sarcina termică a grinzilor condensatoarelor încorporate, iar în caz că se lucrează după curba de sarcină a energiei electrice această economie se micșorează semnificativ.

Cuvinte-cheie
теплофикационная паровая турбина, конденсатор, встроенный пучок, подогрев подпиточной воды, регулирующая диафрагма, математическая модель, энергетическая эффективность.