Assessing the Biological and Mechanical Quality of the Implant Bone Complex Using Medical Micro Technologies
Închide
Articolul precedent
Articolul urmator
273 1
Ultima descărcare din IBN:
2023-03-01 09:56
SM ISO690:2012
PĂLĂRIE, Victor, NACU, Viorel. Assessing the Biological and Mechanical Quality of the Implant Bone Complex Using Medical Micro Technologies. In: Nanotechnologies and Biomedical Engineering, Ed. 5, 3-5 noiembrie 2021, Chişinău. Chişinău: Pontos, 2021, Ediția 5, p. 93. ISBN 978-9975-72-592-7.
EXPORT metadate:
Google Scholar
Crossref
CERIF

DataCite
Dublin Core
Nanotechnologies and Biomedical Engineering
Ediția 5, 2021
Conferința "Nanotechnologies and Biomedical Engineering"
5, Chişinău, Moldova, 3-5 noiembrie 2021

Assessing the Biological and Mechanical Quality of the Implant Bone Complex Using Medical Micro Technologies


Pag. 93-93

Pălărie Victor, Nacu Viorel
 
”Nicolae Testemițanu” State University of Medicine and Pharmacy
 
 
Disponibil în IBN: 18 noiembrie 2021


Rezumat

Reconstruction of bone atrophies and rehabilitation using dental implants are often evaluated based on biologic aspects. As reconstructed jaw also has to ensure primary implant stability, the goals of this study were to determine the mechanical quality of regenerated bone and to investigate potential correlations of intraoperative bone density testing with morphological variables ofstability of implants inserted in non-augmented bone. Ten minipigs were allocated for experiments. After extractions of mandibular premolars, four implants each were placed in a total of four minipigs. Bone density was determined by applying compressive tests using the BoneProbe. Implant insertion torque and resonance frequency analysis were used to evaluate implant stability. Morphological parameters were quantified after harvesting bone sections. Other six minipigs were distributed with four lower jaw experimental sites each following teeth extractions. Xenograft substitutes as well as autogenously bone were used for augmenting threewalled defects, while native tissue served as the control. During implant placement procedures bone quality was determined using intraoperative compressive testing, insertion torque, and resonance frequency analysis. Histologically was determined bone mineral density and bone-implant contact. Assuming that the weak correlations observed were due to the limited sample size, studies at a much greater scale involving various implant systems would however be required.