Increasing energy efficiency of the gases production process in bakery ovens
Закрыть
Articolul precedent
Articolul urmator
498 0
SM ISO690:2012
CHELMENCIUC, Corina. Increasing energy efficiency of the gases production process in bakery ovens. In: International Conference on Energy and Environment: CIEM 2017, Ed. 8, 19-20 octombrie 2017, București. New Jersey, SUA: Institute of Electrical and Electronics Engineers Inc., 2017, Ediția a 8-a, p. 0. ISBN 978-153863943-6. DOI: https://doi.org/10.1109/CIEM.2017.8120830
EXPORT metadate:
Google Scholar
Crossref
CERIF

DataCite
Dublin Core
International Conference on Energy and Environment
Ediția a 8-a, 2017
Conferința "8th International Conference on Energy and Environment"
8, București, Romania, 19-20 octombrie 2017

Increasing energy efficiency of the gases production process in bakery ovens

DOI: https://doi.org/10.1109/CIEM.2017.8120830

Pag. 0-0

Chelmenciuc Corina
 
Universitatea Tehnică a Moldovei
 
Disponibil în IBN: 14 martie 2022


Rezumat

 The current work presents the solution of increasing energy efficiency of the processes of obtaining gases, used as heat carrier for baking processes in tunnel type ovens, by integration of cogeneration. A comparative energetic analysis was carried out between the processes of obtaining gases in bakery ovens and those with integrated cogeneration. The evaluation of energy efficiency, of the proposed technical solution, is based on drawing up the energy balance of processes, the one with gases production in the combustion chamber of classic bakery oven and that of the internal combustion engine. The evaluation of energy efficiency of the classical gas production process in the tunnel type oven is based on experimental data whereas the efficiency of method proposed in this work is based on theoretical data. The energetic analysis was performed in order to demonstrate that the integration of a cogeneration installation in bakery ovens contribute to reducing losses in the processes of obtaining gases, thus increasing the energy efficiency. 

Cuvinte-cheie
bakery oven, energy efficiency, energy losses, Integrated cogeneration, Internal combustion engine

Cerif XML Export

<?xml version='1.0' encoding='utf-8'?>
<CERIF xmlns='urn:xmlns:org:eurocris:cerif-1.5-1' xsi:schemaLocation='urn:xmlns:org:eurocris:cerif-1.5-1 http://www.eurocris.org/Uploads/Web%20pages/CERIF-1.5/CERIF_1.5_1.xsd' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' release='1.5' date='2012-10-07' sourceDatabase='Output Profile'>
<cfResPubl>
<cfResPublId>ibn-ResPubl-151787</cfResPublId>
<cfResPublDate>2017</cfResPublDate>
<cfVol>Ediția a 8-a</cfVol>
<cfISBN>978-153863943-6</cfISBN>
<cfURI>https://ibn.idsi.md/ro/vizualizare_articol/151787</cfURI>
<cfTitle cfLangCode='RO' cfTrans='o'>Increasing energy efficiency of the gases production process in bakery ovens</cfTitle>
<cfKeyw cfLangCode='RO' cfTrans='o'>bakery oven; energy efficiency; energy losses; Integrated cogeneration; Internal combustion engine</cfKeyw>
<cfAbstr cfLangCode='EN' cfTrans='o'><p>&nbsp;</p><p>The current work presents the solution of increasing energy efficiency of the processes of obtaining gases, used as heat carrier for baking processes in tunnel type ovens, by integration of cogeneration. A comparative energetic analysis was carried out between the processes of obtaining gases in bakery ovens and those with integrated cogeneration. The evaluation of energy efficiency, of the proposed technical solution, is based on drawing up the energy balance of processes, the one with gases production in the combustion chamber of classic bakery oven and that of the internal combustion engine. The evaluation of energy efficiency of the classical gas production process in the tunnel type oven is based on experimental data whereas the efficiency of method proposed in this work is based on theoretical data. The energetic analysis was performed in order to demonstrate that the integration of a cogeneration installation in bakery ovens contribute to reducing losses in the processes of obtaining gases, thus increasing the energy efficiency.&nbsp;</p></cfAbstr>
<cfResPubl_Class>
<cfClassId>eda2d9e9-34c5-11e1-b86c-0800200c9a66</cfClassId>
<cfClassSchemeId>759af938-34ae-11e1-b86c-0800200c9a66</cfClassSchemeId>
<cfStartDate>2017T24:00:00</cfStartDate>
</cfResPubl_Class>
<cfResPubl_Class>
<cfClassId>e601872f-4b7e-4d88-929f-7df027b226c9</cfClassId>
<cfClassSchemeId>40e90e2f-446d-460a-98e5-5dce57550c48</cfClassSchemeId>
<cfStartDate>2017T24:00:00</cfStartDate>
</cfResPubl_Class>
<cfPers_ResPubl>
<cfPersId>ibn-person-26966</cfPersId>
<cfClassId>49815870-1cfe-11e1-8bc2-0800200c9a66</cfClassId>
<cfClassSchemeId>b7135ad0-1d00-11e1-8bc2-0800200c9a66</cfClassSchemeId>
<cfStartDate>2017T24:00:00</cfStartDate>
</cfPers_ResPubl>
</cfResPubl>
<cfPers>
<cfPersId>ibn-Pers-26966</cfPersId>
<cfPersName_Pers>
<cfPersNameId>ibn-PersName-26966-2</cfPersNameId>
<cfClassId>55f90543-d631-42eb-8d47-d8d9266cbb26</cfClassId>
<cfClassSchemeId>7375609d-cfa6-45ce-a803-75de69abe21f</cfClassSchemeId>
<cfStartDate>2017T24:00:00</cfStartDate>
<cfFamilyNames>Chelmenciuc</cfFamilyNames>
<cfFirstNames>Corina</cfFirstNames>
</cfPersName_Pers>
</cfPers>
</CERIF>