Conţinutul numărului revistei |
Articolul precedent |
Articolul urmator |
412 0 |
SM ISO690:2012 MIRON, Constantin, MIRON, Livia, CIOBANU, Adrian Alexandru, PUŞCAŞU, Ionel, IACOB, Adrian. Calificarea şi omologarea climatică a echipamentelor de mare putere din domeniul securităţii energetice, telecomunicaţii, sisteme aeriene şi navale. In: Buletinul INCERCOM, 2015, nr. 6, pp. 54-62. ISSN 1857-3762. |
EXPORT metadate: Google Scholar Crossref CERIF DataCite Dublin Core |
Buletinul INCERCOM | ||
Numărul 6 / 2015 / ISSN 1857-3762 | ||
|
||
Pag. 54-62 | ||
Rezumat | ||
This paper presents the achievements of laboratory IHS, Iasi Branch NIRD URBAN-INCERC in the integration domain of the development of scientific research and laboratory tests for checking the operation and reliability of electric equipment of medium and high power in severe weather conditions, such as: - Laboratory testing stage on climate environment actions, on buildings, equipments, machineries, installations and industrial products; - Laboratory testing stage for climate qualification and approval of power equipments in the field of energy security, telecommunications, air and naval systems; - Stage of experimental research and safety testing in the field of performance of buildings dynamic action, seismic, seismic response quantification of micro and macro seism. The paper shoes a case study through a short description, of a complex sequence of experimental initial type checks for COMPACT TRANSFORMER SUBSTATION ENVELOPE, of type Alfa Power DG2061, manufactured in Romania, according to the specification DG10062RO pct. 4 acknowledged by ENEL. |
||
|