Hollow silicon microstructures for biomedical applications
Închide
Articolul precedent
Articolul urmator
612 8
Ultima descărcare din IBN:
2023-01-26 14:34
SM ISO690:2012
POSTICA, Vasile, HOLKEN, Iris, BUMKE, Lars, BAUM, M., ABABII, Nicolai, LUPAN, Oleg, ADELUNG, Rainer. Hollow silicon microstructures for biomedical applications. In: Health Technology Management: 3rd International Conference, Ed. 3, 6-7 octombrie 2016, Chișinău. Chișinău, Republica Moldova: Technical University of Moldova, 2016, Editia 3, p. 121.
EXPORT metadate:
Google Scholar
Crossref
CERIF

DataCite
Dublin Core
Health Technology Management
Editia 3, 2016
Conferința "Health Technology Management"
3, Chișinău, Moldova, 6-7 octombrie 2016

Hollow silicon microstructures for biomedical applications


Pag. 121-121

Postica Vasile1, Holken Iris2, Bumke Lars2, Baum M.2, Ababii Nicolai1, Lupan Oleg12, Adelung Rainer2
 
1 Technical University of Moldova,
2 Institute for Material Science, Christian-Albrechts-University of Kiel
 
Proiecte:
 
Disponibil în IBN: 3 aprilie 2019


Rezumat

Traditional gas sensors and biosensors based on metal oxide micro- and nanostructures, which are widely investigated in the past decades, have very high electrical resistivity (in range of MΩ – TΩ). Such high resistivity is usually measured in laboratory conditions with special high-cost measurement units or equipment. Thus, such sensors are complicated to integrate into electronic biomedical devices or complementary metal-oxide-semiconductor (CMOS) systems, and needs high-cost amplifiers with very high input impedance [1-3]. In this context, silicon (Si) materials which play a central role in semiconductor industry [3], by rational controlling of morphology and physicochemical properties can be easily integrated in gas sensors and biosensors devices. Recently Adelungs’ group demonstrated a novel method to synthesize hollow three-dimensional (3-D) aero-silicon microstructures [3], which demonstrated excellent potential for the development of biomedical applications, i.e. human breath analysis. Fig. 1a shows the SEM image of a hollow micro-Si-tetrapod (T). The upper arm is open and demonstrates that the Si-T is hollow. The wall thickness is in the range of 20 – 100 nm. Based on a single Si-T arm, a micro-device was fabricated (see Fig. 1b) by the procedure described earlier [4]. The diameter of the arm was ≈ 1 μm at one end and ≈ 2.5 μm at another end. The current – voltage characteristic demonstrates the formation of Ohmic contacts at both ends of the Si-T arm (see Fig. 1c). Figure 1. SEM images of: (a) hollow Si-T and (b) of fabricated micro-device based on an individual Si-T arm. (c) Current – voltage characteristic of the micro-device on Si-T. (d) Gas response of micro-device to 50 ppm of acetone vapour. First pulse is applied at 30% RH, the other 2 peaks are applied at 70% RH. It was demonstrated by clinical investigations/researches that diabetes patients have higher concentration of acetone vapour in their breath, compared to healthy peoples [3]. Thus, acetone vapour can be used as excellent marker for the diagnosis of diabetes mellitus in human breath, which contains a high value of relative humidity (RH). The fabricated micro-device was exposed to 50 ppm of acetone vapour at room temperature in 30% RH (see Fig. 1d first pulse) and 70% RH (see Fig. 1d least 2 pulses). It was found that the micro-device posses good gas response for 30% (Rgas/Rair ≈ 6.3). By increase RH value to 70% the gas response decrease with only 15%. It demonstrates the potential of Si-T micro-structures to develop portable and miniature breath-monitoring devices with low dependence on RH value and low power consumption.