Operating Reliability Evaluation of Distribution Networks 10 kV
Închide
Articolul precedent
Articolul urmator
786 6
Ultima descărcare din IBN:
2023-02-27 21:19
Căutarea după subiecte
similare conform CZU
621.311.1.019.3 (1)
Electrotehnică (1154)
SM ISO690:2012
BOŞNEAGA, Valeriu, SUSLOV, Victor, POSTOLATY, Vitaly M.. Operating Reliability Evaluation of Distribution Networks 10 kV. In: Sielmen: Proceedings of the 10th international conference on electromechanical and power systems, Ed. 10, 6-9 octombrie 2015, Craiova. Craiova, România: Editura ALMA, 2015, Ediția 10, pp. 177-179. ISBN 978-606-567-284-0.
EXPORT metadate:
Google Scholar
Crossref
CERIF

DataCite
Dublin Core
Sielmen
Ediția 10, 2015
Conferința "Sielmen"
10, Craiova, Romania, 6-9 octombrie 2015

Operating Reliability Evaluation of Distribution Networks 10 kV

CZU: 621.311.1.019.3

Pag. 177-179

Boşneaga Valeriu, Suslov Victor, Postolaty Vitaly M.
 
Institute of Power Engineering of ASM
 
 
Disponibil în IBN: 6 august 2018


Rezumat

Mathematical model for description of flexible alternative current link for connecting power systems with the same rate of frequency is described. The model allows estimating the oscillations of transmitted instantaneous and active powers at different steps of angle adjusting and for other parameters of considered flexible coupling between power systems. Obtained results allow estimating the upper limit of the switching time, which is necessary to ensure by means of semiconductor switching devices the implementation of the adopted algorithm of angle control. The investigation results could be used as the initial step for the development of phase-shifting transformer (PST) with circular phase angle regulation and control systems, ensuring joint operation of power systems with the same nominal frequency of the alternating current.

Cuvinte-cheie
flexible alternative current link, phase-shifting transformer

DataCite XML Export

<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' xmlns='http://datacite.org/schema/kernel-3' xsi:schemaLocation='http://datacite.org/schema/kernel-3 http://schema.datacite.org/meta/kernel-3/metadata.xsd'>
<creators>
<creator>
<creatorName>Boşneaga, V.A.</creatorName>
<affiliation>Institutul de Energetica al AŞM, Moldova, Republica</affiliation>
</creator>
<creator>
<creatorName>Suslov, V.M.</creatorName>
<affiliation>Institutul de Energetica al AŞM, Moldova, Republica</affiliation>
</creator>
<creator>
<creatorName>Postolati, V.M.</creatorName>
<affiliation>Institutul de Energetica al AŞM, Moldova, Republica</affiliation>
</creator>
</creators>
<titles>
<title xml:lang='en'>Operating Reliability Evaluation of Distribution Networks 10 kV</title>
</titles>
<publisher>Instrumentul Bibliometric National</publisher>
<publicationYear>2015</publicationYear>
<relatedIdentifier relatedIdentifierType='ISBN' relationType='IsPartOf'>978-606-567-284-0</relatedIdentifier>
<subjects>
<subject>flexible alternative current link</subject>
<subject>phase-shifting
transformer</subject>
<subject schemeURI='http://udcdata.info/' subjectScheme='UDC'>621.311.1.019.3</subject>
</subjects>
<dates>
<date dateType='Issued'>2015</date>
</dates>
<resourceType resourceTypeGeneral='Text'>Conference Paper</resourceType>
<descriptions>
<description xml:lang='en' descriptionType='Abstract'><p>Mathematical model for description of flexible alternative current link for connecting power systems with the same rate of frequency is described. The model allows estimating the oscillations of transmitted instantaneous and active powers at different steps of angle adjusting and for other parameters of considered flexible coupling between power systems. Obtained results allow estimating the upper limit of the switching time, which is necessary to ensure by means of semiconductor switching devices the implementation of the adopted algorithm of angle control. The investigation results could be used as the initial step for the development of phase-shifting transformer (PST) with circular phase angle regulation and control systems, ensuring joint operation of power systems with the same nominal frequency of the alternating current.</p></description>
</descriptions>
<formats>
<format>application/pdf</format>
</formats>
</resource>