Articolul precedent |
Articolul urmator |
274 0 |
SM ISO690:2012 MELNIC, Svetlana, CHELE, Nicolae. Implanto-prosthetic treatment with early loading of dental implants. In: Cercetarea în biomedicină și sănătate: calitate, excelență și performanță, Ed. 1, 20-22 octombrie 2021, Chişinău. Chișinău, Republica Moldova: 2021, p. 460. ISBN 978-9975-82-223-7 (PDF).. |
EXPORT metadate: Google Scholar Crossref CERIF DataCite Dublin Core |
Cercetarea în biomedicină și sănătate: calitate, excelență și performanță 2021 | ||||||
Conferința "Cercetarea în biomedicină și sănătate: calitate, excelență și performanță" 1, Chişinău, Moldova, 20-22 octombrie 2021 | ||||||
|
||||||
Pag. 460-460 | ||||||
|
||||||
Descarcă PDF | ||||||
Rezumat | ||||||
Background. In recent years, implant dentistry has seen unparalleled technological advances, both surgical and prosthetic. Simultaneously with this technological revolution in the field of implant dentistry, the literature abounds more and more in longitudinal studies. Objective of the study. Study and analysis of the particularities of the implant-prosthetic treatment with early functional loading to reduce the loading terms of endosseous dental implants. Material and Methods. Lately, more and more followers of the method of early loading of dental implants with the restoration of the lost functions of edentulous patients are appearing among implantologists. The problems of dynamic processes occurring on the surface of dental implants and their importance in terms of biomechanics have been addressed by many scientists and it has been established that primary implant. Results. Tawse-Smith et al., Reported 71% survival rate in the group of early loading of dental implants. However, Payne et al. reported periotest values after 1 year in the early loading group were - 4.12 compared to -3.84 at the beginning of the first year; after 2 years these values were -4.52 -4.74 and, consequently, the values increase, which indicates a satisfactory stability, as well as a good osseointegration. Conclusion. In the practical implementation of early functional loading protocols, they led to the primary stability of the dental implant with their early loading after 3-4 weeks after implantation, which favored the faster restoration of the aesthetic and functional appearance. |
||||||
Cuvinte-cheie dental implant, loading early (premature), dental arches, dental migration, mplanturi dentare, încărcare precoce (prematură), arcade dentare, migrări dentare |
||||||
|