Articolul precedent |
Articolul urmator |
742 6 |
Ultima descărcare din IBN: 2023-07-28 11:13 |
Căutarea după subiecte similare conform CZU |
621.314.21 (4) |
Electrotehnică (1154) |
SM ISO690:2012 BOŞNEAGA, Valeriu, SUSLOV, Victor. Three-phase Three Legs Power Transformers Asymmetrical Modes Study for Zigzag Windings Connection. In: Управляемые электропередачи: Сборник трудов лаборатории управляемых электропередач Института энергетики АН Молдовы, 1 ianuarie 2007 - 31 decembrie 2017, Chişinău. Chișinău, Republica Moldova: Институт энергетики, 2017, pp. 24-29. |
EXPORT metadate: Google Scholar Crossref CERIF DataCite Dublin Core |
Управляемые электропередачи 2017 | ||||||
Sesiunea "Управляемые электропередачи" Chişinău, Moldova, 1 ianuarie 2007 - 31 decembrie 2017 | ||||||
|
||||||
CZU: 621.314.21 | ||||||
Pag. 24-29 | ||||||
|
||||||
Descarcă PDF | ||||||
Rezumat | ||||||
Based on the previously proposed model the simulations were made and characteristic features |
||||||
Cuvinte-cheie Power Transformer, core type, three limbs, asymmetric modes, zigzag, zero sequence, magnetic flux |
||||||
|
Dublin Core Export
<?xml version='1.0' encoding='utf-8'?> <oai_dc:dc xmlns:dc='http://purl.org/dc/elements/1.1/' xmlns:oai_dc='http://www.openarchives.org/OAI/2.0/oai_dc/' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' xsi:schemaLocation='http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd'> <dc:creator>Boşneaga, V.A.</dc:creator> <dc:creator>Suslov, V.M.</dc:creator> <dc:date>2017</dc:date> <dc:description xml:lang='en'><p>Based on the previously proposed model the simulations were made and characteristic features<br />of steady asymmetric modes of three-phase core type (three leg) transformer were investigated for zigzag<br />winding connection, taking into consideration the electromagnetic coupling of windings, located on<br />different legs. Calculations and analysis were conducted based on distribution transformer 100 kVA,<br />10/0.4 kV and include the most typical steady unbalanced conditions, arising at various short circuits,<br />including those, accompanied by the presence of zero sequence magnetic flux. For the considered modes<br />vector diagrams of currents and voltages, as well as the relative values of the magnetic flux were<br />constructed, which provide a clear visual representation of their features. It was demonstrated, that if the<br />numbers of secondary windings turns are unequal, zigzag scheme no longer has advantages in asymmetric<br />modes. These advantages also disappear at single-phase short-circuit of one secondary winding.<br />Additional measures should be taken for the reliable protection against such short-circuits and prevention<br />of transformer damage.</p></dc:description> <dc:source>Управляемые электропередачи () 24-29</dc:source> <dc:subject>Power Transformer</dc:subject> <dc:subject>core type</dc:subject> <dc:subject>three limbs</dc:subject> <dc:subject>asymmetric modes</dc:subject> <dc:subject>zigzag</dc:subject> <dc:subject>zero sequence</dc:subject> <dc:subject>magnetic flux</dc:subject> <dc:title>Three-phase Three Legs Power Transformers Asymmetrical Modes Study for Zigzag Windings Connection</dc:title> <dc:type>info:eu-repo/semantics/article</dc:type> </oai_dc:dc>