Interdependenţa factorilor de risc şi a indicilor spirometrici în maladiile respiratorii cronice
Close
Conţinutul numărului revistei
Articolul precedent
Articolul urmator
877 7
Ultima descărcare din IBN:
2023-04-06 14:37
SM ISO690:2012
CAZACU-STRATU, Angela, SELIVESTRU, Rodica. Interdependenţa factorilor de risc şi a indicilor spirometrici în maladiile respiratorii cronice . In: Buletinul Academiei de Ştiinţe a Moldovei. Ştiinţe Medicale, 2012, nr. 1(33), pp. 148-151. ISSN 1857-0011.
EXPORT metadate:
Google Scholar
Crossref
CERIF

DataCite
Dublin Core
Buletinul Academiei de Ştiinţe a Moldovei. Ştiinţe Medicale
Numărul 1(33) / 2012 / ISSN 1857-0011

Interdependenţa factorilor de risc şi a indicilor spirometrici în maladiile respiratorii cronice

Pag. 148-151

Cazacu-Stratu Angela, Selivestru Rodica
 
Universitatea de Stat de Medicină şi Farmacie „Nicolae Testemiţanu“
 
Disponibil în IBN: 2 decembrie 2013


Rezumat

Au fost investigaţi elevii claselor I-IV din 5 licee din mun. Chişinău, pentru aprecierea indicilor spirografi ci şi corelaţia acestora cu factorii de instruire şi habituali. S-a stabilit că în maladiile respiratorii cronice indicii spirometriei au valori reduse, fapt ce corelează direct cu gradul de severitate a maladiilor. Cea mai mare valoare a coefi cientului de corelaţie a fost înregistrată între indicii pirografi ci (FVC, FEV1), umiditatea relativă şi concentraţia de CO2 în aer (r>0,6). Condiţiile nefavorabile multifactoriale, de asemenea, corelează direct cu severitatea maladiei. După estimarea factorilor de risc s-a decelat, că pe primul loc se situează igrasia, mucegaiul şi umiditatea sporită în locuinţe, care prezintă factori importanţi în declanşarea acceselor de astm bronşic şi dezvoltarea bronşitei cronice.

There were investigated the Spiro metric indices and correlation of it with habitual and school factors from five schools of Chişinau at pupils I-IV classes from. It was established that in chronic respiratory disease Spiro metric indices were at below values and there were the direct correlation with the grade of severity of diseases. Very big correlation coefficient it was registered between Spiro metric index (FVC, FEV1) and the relative humidity at the air and the concentration of the CO2 (r>0,6). Also, the multifactor unfavorable conditions were correlated directly with severity of diseases. After estimation of the risk of factors it was determinates, that on the first place it situated of dampens, mildew and high humidity in homes, what were showed important factors in the triggering of the access asthma and development of chronic bronchitis.

Были исследованы учащиеся I-IV классов из 5 муниципальных школ, для определения спирометрических индексов и их корреляции с жилищными условиями и условиями обучения. При хронических респираторных заболеваниях было установлено, что спирометрические индексы имеют низкие значения, которые напрямую коррелируют с тяжестью заболевания. Высокие показатели коэффициента корреляции были выявлены между спирометрическими индексами, влажностью и концентрацией CO2 в воздухе (г>0,6). Также напрямую связаны многофакторные неблагоприятные условия с тяжестью заболеваний. После оценки факторов риска было выявлено что на первом месте находится сырость, плесень и высокий уровень влажности в помещениях, которые представляют большое значение в распространении бронхиальной астмы и развитии хронического бронхита.