Impact of DC bias on the magnetic loading of three phase three limb transformer based on finite element method
Close
Articolul precedent
Articolul urmator
349 0
SM ISO690:2012
KOHLI, Saurabh, MAHAJAN, Sagar Bhaskar, SANJEEVIKUMAR, Padmanaban, FEDAK, Viliam, OLESCHUK, Valentin. Impact of DC bias on the magnetic loading of three phase three limb transformer based on finite element method. In: Lecture Notes in Electrical Engineering, 11 octombrie 2017, Dusseldorf. Dusseldorf, Germania: Springer Verlag, 2017, Vol. 436, pp. 97-106. ISSN 18761100. DOI: https://doi.org/10.1007/978-981-10-4394-9_10
EXPORT metadate:
Google Scholar
Crossref
CERIF

DataCite
Dublin Core
Lecture Notes in Electrical Engineering
Vol. 436, 2017
Sesiunea "Lecture Notes in Electrical Engineering"
Dusseldorf, Germania, 11 octombrie 2017

Impact of DC bias on the magnetic loading of three phase three limb transformer based on finite element method

DOI:https://doi.org/10.1007/978-981-10-4394-9_10

Pag. 97-106

Kohli Saurabh1, Mahajan Sagar Bhaskar1, Sanjeevikumar Padmanaban2, Fedak Viliam3, Oleschuk Valentin4
 
1 Marathwada Institute of Technology, Aurangabad,
2 University of Johannesburg,
3 Technical University of Košice,
4 Institute of Power Engineering of ASM
 
 
Disponibil în IBN: 4 iunie 2022


Rezumat

 This article proposes a modelling mechanism based on Finite Element Method (FEM) to understand the impact of DC currents on the magnetic loading of the transformer. It details on the way magnetizing currents vary and harmonics develop in a transformer. The analysis is performed using ANSYS tool for generating the scaled transformer model and MATLAB for plotting the results. The analysis shows that on varying the primary voltage to different levels of voltages and injecting DC currents based on a weakly coupled multi harmonic approach the three phase three limb transformer is subjected to varying magnetizing currents with the development of odd harmonics based on the saturation level of transformer. The even harmonics are not observed owning to the structure of three phase three limb transformer which offers a high reluctance to DC flux. Furthermore the scaled transformer is observed in ANSYS and it is visualized that the stray fluxes and the saturation levels of the three limb transformer raises to a higher level on impact of DC currents of varying magnitudes.

Cuvinte-cheie
DC bias, Geo-magnetically induced currents, Half cycle saturation Harmonics, Magnetizing currents, Three phase transformer model